Home / Concrete / Development Length of Rebar
Development Length of Rebar
Quick answer: Development (anchorage) length is the length of bar that must be embedded in concrete so the bar can reach its design stress without pulling out. For a 16 mm bar in tension it works out to about 48φ (IS 456, M25, Fe500), 40φ (BS 8110, fcu 30, fy 500), 36φ (Eurocode 2, C30/37, good bond) and 38φ (ACI 318, 28 MPa, Grade 420). The four codes use different formulas, so never mix values between them.
Development length governs how far bars extend past supports, into columns and footings, and how long laps must be. All four major codes start from the same idea: the bond stress around the bar's surface must balance the force in the bar. They differ in how they set the bond stress and the safety factors.
The common principle
(π φ² / 4) × σs = (π φ) × Ld × fb
⇒ Ld = φ σs / (4 fb)
where φ is the bar diameter, σs the design stress in the bar and fb the design bond stress. Each code below is a version of this equation.
IS 456:2000 (India)
τbd is the design bond stress for plain bars in tension (cl. 26.2.1.1): 1.2 N/mm² for M20, 1.4 for M25, 1.5 for M30, 1.7 for M35 and 1.9 for M40 and above. For deformed bars (Fe415, Fe500) increase it by 60%, and for bars in compression by a further 25%.
| Concrete | Fe415, tension | Fe500, tension | Fe500, compression |
|---|---|---|---|
| M20 | 47.0φ | 56.6φ | 45.3φ |
| M25 | 40.3φ | 48.5φ | 38.8φ |
| M30 | 37.6φ | 45.3φ | 36.2φ |
| M35 | 33.2φ | 40.0φ | 32.0φ |
| M40 | 29.7φ | 35.8φ | 28.6φ |
BS 8110-1:1997 (UK, still used in Malaysia and elsewhere)
For type 2 deformed bars, β = 0.50 in tension and 0.63 in compression. The results below match BS 8110 Table 3.27 (for example 37φ for fcu = 30 with fy = 460).
| fcu (N/mm²) | fy 460, tension | fy 500, tension |
|---|---|---|
| 25 | 40.0φ | 43.5φ |
| 30 | 36.5φ | 39.7φ |
| 35 | 33.8φ | 36.8φ |
| 40 | 31.6φ | 34.4φ |
Eurocode 2 (EN 1992-1-1)
fbd = 2.25 η1 η2 fctd (cl. 8.4.2)
lbd = α1α2α3α4α5 lb,rqd ≥ lb,min
η1 = 1.0 for "good" bond conditions and 0.7 for "poor" (for example, top bars in deep pours); η2 = 1.0 for φ ≤ 32 mm. fctd = fctk,0.05 / 1.5. The table assumes σsd = fyd = 500/1.15 = 435 N/mm² and all α factors = 1.0, which is conservative for straight bars.
| Concrete | fbd (N/mm²) | lb,rqd, good bond | lb,rqd, poor bond |
|---|---|---|---|
| C20/25 | 2.25 | 48.3φ | 69.0φ |
| C25/30 | 2.70 | 40.3φ | 57.5φ |
| C30/37 | 3.00 | 36.2φ | 51.8φ |
| C35/45 | 3.30 | 32.9φ | 47.1φ |
| C40/50 | 3.75 | 29.0φ | 41.4φ |
The minimum in tension is lb,min = max(0.3 lb,rqd, 10φ, 100 mm). Check your National Annex: the UK Annex keeps αct = 1.0 for bond, as used here.
ACI 318-19 (USA)
The simplified expressions of Table 25.4.2.3 (SI units, clear spacing and cover meeting the table's conditions):
No. 22 and larger: ld = fy ψt ψe / (1.7 λ √f′c) × db
ld ≥ 300 mm
| f′c (MPa) | Grade 420, bars ≤ No. 19 | Grade 420, bars ≥ No. 22 |
|---|---|---|
| 21 | 43.6 db | 53.9 db |
| 28 | 37.8 db | 46.7 db |
| 35 | 33.8 db | 41.8 db |
Values assume uncoated bottom bars in normal-weight concrete (ψt = ψe = λ = 1.0). Top bars with more than 300 mm of fresh concrete below them take ψt = 1.3.
Worked example: 16 mm bar in tension
| Code | Assumptions | Ratio | Length for φ16 |
|---|---|---|---|
| IS 456 | M25, Fe500 | 48.5φ | 777 mm |
| BS 8110 | fcu 30, fy 500 | 39.7φ | 635 mm |
| EC2 | C30/37, good bond, α = 1 | 36.2φ | 580 mm |
| ACI 318 | 28 MPa, Grade 420 | 37.8db | 605 mm |
The spread looks large, but each code pairs its anchorage rule with its own material factors and detailing rules. Use one code consistently through a design.
Practical points
- Reduce by the stress actually needed. All four codes let you reduce the length when the bar is not fully stressed (As,req / As,prov), subject to minimums.
- Bends and hooks help. Standard hooks count towards anchorage, so a bar entering a narrow column can be hooked instead of running straight.
- Top bars need more. Poor bond (EC2) or ψt = 1.3 (ACI) adds 30–43% for top bars in deep members.
FAQ
Is development length the same as lap length?
No. Lap length is based on development length but is usually longer: EC2 multiplies by α6 (up to 1.5), IS 456 takes the larger of Ld and 30φ, and ACI Class B splices use 1.3 ld.
Why does development length fall as concrete gets stronger?
Bond strength rises with concrete tensile strength, so a shorter length can transfer the same bar force.
What does 40φ mean on a drawing?
40 times the bar diameter. For a 20 mm bar, 40φ = 800 mm.
References
- IS 456:2000, Plain and reinforced concrete: code of practice, cl. 26.2.
- BS 8110-1:1997, Structural use of concrete, cl. 3.12.8 and Table 3.27.
- EN 1992-1-1:2004, Eurocode 2: Design of concrete structures, Section 8.
- ACI 318-19, Building code requirements for structural concrete, Chapter 25.
Written by Engr. Abdul Latif, civil and structural engineer. Last reviewed: 16 November 2026. Check the code edition and National Annex that apply to your project.
