Home / Engineering / Beam Deflection Formulas
Beam Deflection Formulas
Quick answer: Maximum deflection of a simply supported beam under a uniform load is δ = 5wL⁴ / (384EI); with a central point load it is PL³ / (48EI). A cantilever deflects wL⁴ / (8EI) under uniform load and PL³ / (3EI) under an end load. The table below gives the maximum moment and deflection for the eight cases engineers use most.
Deflection checks often govern long-span beams, especially in steel and timber. These are the standard elastic formulas for prismatic beams (constant EI), with a worked steel example and the usual limits.
Free calculator: beam deflection, shear force and bending moment
Standard cases
| Support and load | Max moment | Max deflection | Where |
|---|---|---|---|
| Simply supported, uniform load w | wL²/8 | 5wL⁴/(384EI) | Midspan |
| Simply supported, central point load P | PL/4 | PL³/(48EI) | Midspan |
| Simply supported, two equal loads P at third points | PL/3 | 23PL³/(648EI) | Midspan |
| Cantilever, uniform load w | wL²/2 | wL⁴/(8EI) | Free end |
| Cantilever, end point load P | PL | PL³/(3EI) | Free end |
| Fixed both ends, uniform load w | wL²/12 (at supports) | wL⁴/(384EI) | Midspan |
| Fixed both ends, central point load P | PL/8 | PL³/(192EI) | Midspan |
| Propped cantilever, uniform load w | wL²/8 (at fixed end) | wL⁴/(185EI) | 0.42L from the pin |
w is load per unit length, P a point load, L the span, E the elastic modulus and I the second moment of area. Keep units consistent: N, mm and N/mm² work well.
Worked example: steel beam, 6 m span
Given: simply supported, L = 6,000 mm, variable (imposed) load w = 10 kN/m = 10 N/mm, E = 210,000 N/mm², I = 95.1 × 10⁶ mm⁴ (the 300 mm deep I-section from our area moment of inertia example).
= 6.48 × 10¹⁶ / 7.67 × 10¹⁵
= 8.4 mm
Typical limit for imposed-load deflection of a beam carrying a brittle finish is L/360 = 16.7 mm, and L/250 = 24 mm for general use. 8.4 mm passes both. The maximum moment is wL²/8 = 10 × 6²/8 = 45 kNm, which you would check separately for strength.
Combining load cases
For elastic beams, deflections from different loads simply add (superposition). A beam with a uniform load and a central point load deflects 5wL⁴/(384EI) + PL³/(48EI) at midspan.
Typical deflection limits
| Member | Common limit | Source |
|---|---|---|
| Steel beams carrying plaster or brittle finish (imposed load) | span/360 | UK NA to BS EN 1993-1-1 (guidance) |
| Other steel beams (imposed load) | span/200 | UK NA to BS EN 1993-1-1 (guidance) |
| Steel cantilevers | length/180 | UK NA to BS EN 1993-1-1 (guidance) |
| Concrete beams and slabs (total, appearance) | span/250 | EN 1992-1-1 cl. 7.4.1 |
| Concrete, after finishes are installed | span/500 | EN 1992-1-1 cl. 7.4.1 |
Your project specification or client may set tighter limits, for example for glazing or sensitive equipment.
Things that change the answer
- Concrete cracks and creeps. These formulas give short-term elastic deflection. Reinforced concrete needs cracked-section stiffness and long-term creep; EC2 and ACI give methods, or use span/depth ratios.
- Shear deformation. Ignored here; it matters only for short, deep beams.
- Partial fixity. Real connections are neither perfectly pinned nor fully fixed. The pinned case is the safe upper bound.
FAQ
What is EI?
Flexural rigidity: the product of the material's elastic modulus E and the section's second moment of area I. Doubling either halves the deflection.
What is E for steel and concrete?
Structural steel: 210,000 N/mm² (EC3) or 200,000 N/mm² (AISC). Concrete: about 30,000–35,000 N/mm² for C25–C40 (EC2 Table 3.1, Ecm).
Why is a fixed-ended beam five times stiffer?
For a uniform load, 5wL⁴/384 versus wL⁴/384: the end moments reduce the midspan bending, so the curve flattens.
References
- SCI P363 and the Steel Construction Institute design tables for standard beam formulas.
- UK National Annex to BS EN 1993-1-1, NA.2.23 (vertical deflection guidance).
- EN 1992-1-1:2004, cl. 7.4 (deflection control).
- AISC Steel Construction Manual, Table 3-23 (shears, moments and deflections).
Written by Engr. Abdul Latif, civil and structural engineer. Last reviewed: 16 November 2026.